Difference between revisions of "Interferometer shot noise limit"

From amowiki
Jump to navigation Jump to search
imported>Ichuang
imported>Tailin
 
(6 intermediate revisions by 4 users not shown)
Line 4: Line 4:
 
photons, the uncertainty <math>\Delta \phi</math> with which an unknown phase
 
photons, the uncertainty <math>\Delta \phi</math> with which an unknown phase
 
<math>\phi</math> can be determined might be bounded below by <math>\Delta \phi \geq
 
<math>\phi</math> can be determined might be bounded below by <math>\Delta \phi \geq
1/\sqrt{n}</math>, based on the heuristic that <math>\Delta n \Delta \phi \geq
+
1/\sqrt{n}</math>, based on the heuristic inequality <math>\Delta n \Delta \phi \geq
 
1</math>.  Such a limit is known as being due to shot noise, arising
 
1</math>.  Such a limit is known as being due to shot noise, arising
 
from the particle nature of photons, as we shall now see rigorously.
 
from the particle nature of photons, as we shall now see rigorously.
 
Consider a Mach-Zehnder interferometer constructed from two 50/50
 
Consider a Mach-Zehnder interferometer constructed from two 50/50
 
beamsplitters, used to measure <math>\phi</math>:
 
beamsplitters, used to measure <math>\phi</math>:
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-mzi.png|thumb|306px|none|]]
+
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-mzi.png|thumb|400px|none|]]
  
 
Let us analyze this interferometer, first by using a traditional
 
Let us analyze this interferometer, first by using a traditional
 
quantum optics approach in the Heisenberg picture, and second by using
 
quantum optics approach in the Heisenberg picture, and second by using
 
single photons in the Schrodinger picture.
 
single photons in the Schrodinger picture.
 +
 +
==== Sensitivity limit for Mach-Zehnder interferometer ====
  
 
Previously, we've defined the unitary transform for a quantum
 
Previously, we've defined the unitary transform for a quantum
Line 27: Line 29:
 
the beamsplitter; in particular,
 
the beamsplitter; in particular,
 
:<math>  
 
:<math>  
\left[ \begin{array}{c}{a-ib}\\{b-ia}\end{array}\right]  = B  \left[ \begin{array}{c}{a}\\{b}\end{array}\right]  
+
\frac{1}{\sqrt{2}} \left[\begin{array}{c}{a-ib}\\{b-ia}\end{array}\right]  = B  \left[ \begin{array}{c}{a}\\{b}\end{array}\right]  
 
\,.
 
\,.
 
</math>
 
</math>
Line 75: Line 77:
 
as <math>\sin\phi</math>, and we shall see that this is the noise on the signal.
 
as <math>\sin\phi</math>, and we shall see that this is the noise on the signal.
 
The average output signal <math> \langle X{\rangle}</math>, as a function of <math>\phi</math>, looks like this:
 
The average output signal <math> \langle X{\rangle}</math>, as a function of <math>\phi</math>, looks like this:
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-balance-point.png|thumb|200px|none|]]
+
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-balance-point.png|thumb|400px|none|]]
  
 
Note that if our goal is to maximize measurement sensitivity to
 
Note that if our goal is to maximize measurement sensitivity to
Line 101: Line 103:
 
</math>
 
</math>
 
Let <math>\phi=\pi/2</math>, such that <math>M=Y</math>, and <math>\partial M/\partial\phi = -X</math>.
 
Let <math>\phi=\pi/2</math>, such that <math>M=Y</math>, and <math>\partial M/\partial\phi = -X</math>.
 +
 +
==== Limit for coherent state input ====
 +
 
For a coherent state input, <math>|\psi_{in} \rangle  = |\alpha{\rangle}|0{\rangle}</math>, we find
 
For a coherent state input, <math>|\psi_{in} \rangle  = |\alpha{\rangle}|0{\rangle}</math>, we find
 
:<math>\begin{array}{rcl}   
 
:<math>\begin{array}{rcl}   
Line 148: Line 153:
 
with <math>\sqrt{n}</math>.  The improvement arises because greater laser power
 
with <math>\sqrt{n}</math>.  The improvement arises because greater laser power
 
allows better distinction between the signals in <math>c</math> and <math>d</math>.
 
allows better distinction between the signals in <math>c</math> and <math>d</math>.
 +
 +
==== Limit for single photons ====
 +
 
Another way to arrive at the same result, using single photons, gives
 
Another way to arrive at the same result, using single photons, gives
 
an alternate interpretation and different insight into the physics.
 
an alternate interpretation and different insight into the physics.
Line 156: Line 164:
 
rotation.  The Mach-Zehnder interferometer we're using can thus be
 
rotation.  The Mach-Zehnder interferometer we're using can thus be
 
expressed as this transform on a single qubit:
 
expressed as this transform on a single qubit:
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-qubit-mzi.png|thumb|200px|none|]]
+
::[[Image:chapter2-quantum-light-part-5-interferometry-l7-qubit-mzi.png|thumb|400px|none|]]
 
where the probability of measuring a single photon at the output is
 
where the probability of measuring a single photon at the output is
 
<math>P</math>.  Walking through this optical circuit, the states are found to be
 
<math>P</math>.  Walking through this optical circuit, the states are found to be
Line 183: Line 191:
 
Given this, the uncertainty in <math>\phi</math> is
 
Given this, the uncertainty in <math>\phi</math> is
 
:<math>  
 
:<math>  
\Delta\phi = \frac{\Delta\phi}
+
\Delta\phi = \frac{\Delta P}
 
{\left| \frac{dP}{d\phi} \right|} = \frac{1}{\sqrt{n}}
 
{\left| \frac{dP}{d\phi} \right|} = \frac{1}{\sqrt{n}}
 
\,.
 
\,.

Latest revision as of 17:45, 10 May 2015

The Poisson distribution of photon number in coherent (laser) light contributes an uncertainty of to optical measurements. It is therefore reasonable to anticipate that with photons, the uncertainty with which an unknown phase can be determined might be bounded below by , based on the heuristic inequality . Such a limit is known as being due to shot noise, arising from the particle nature of photons, as we shall now see rigorously. Consider a Mach-Zehnder interferometer constructed from two 50/50 beamsplitters, used to measure :

Chapter2-quantum-light-part-5-interferometry-l7-mzi.png

Let us analyze this interferometer, first by using a traditional quantum optics approach in the Heisenberg picture, and second by using single photons in the Schrodinger picture.

Sensitivity limit for Mach-Zehnder interferometer

Previously, we've defined the unitary transform for a quantum beamsplitter as being a rotation about the axis, so as to avoid having to keep track of factors of . For variety, let's now use a different definition; nothing essential will change. Let the 50/50 beamsplitter transformation be

This acts on to produce operators describing the output of the beamsplitter; in particular,

Similarly, the phase shifter acting on the mode operators performs

The Mach-Zehnder transform is thus

The way we have defined these transformations here, the output modes of the interferometer, and , are

We are interested in the difference between the photon numbers measured at the two outputs, , where the extra factor of two is introduced for convenience. We find

The measurement result is thus

Define , and . Recognizing that is the difference in photon number between the two output arms, and recalling that this is the main observable result from changing , we identify the signal we wish to see as being .

Ideally, the output signal should go as . The signal due to goes as , and we shall see that this is the noise on the signal. The average output signal , as a function of , looks like this:

Chapter2-quantum-light-part-5-interferometry-l7-balance-point.png

Note that if our goal is to maximize measurement sensitivity to changes in , then the best point to operate the interferometer at is around , since the slope is largest there. At this operating point, if the interferometer's inputs have laser light coming into only one port, then the outputs have equal intensity; thus, the interferometer is sometimes said to be "balanced" when .

What is the uncertainty in our measurement of , derived from the observable ? By propagating uncertainties, this is

where

Let , such that , and .

Limit for coherent state input

For a coherent state input, , we find

if we define as the input state mean photon number. Also,

This is consitent with our intuition: the signal should go as , and the undesired term goes as , so it is good that is small on average. However, there are nontrivial fluctuations in , because

and is nonzero for the coherent state! Specifically, the noise in is

and thus the variance in the measurement result is

From Eq.(\ref{eq:l7-dphi}), it follows that the uncertainty in is therefore

This is a very reasonable result; as the number of photons used increases, the accuracy with which can be determined increases with . The improvement arises because greater laser power allows better distinction between the signals in and .

Limit for single photons

Another way to arrive at the same result, using single photons, gives an alternate interpretation and different insight into the physics.

As we have seen previously, acting on the , "dual-rail" photon state, a 50/50 beamsplitter performs a rotation, and a phase shifter performs a rotation. The Mach-Zehnder interferometer we're using can thus be expressed as this transform on a single qubit:

Chapter2-quantum-light-part-5-interferometry-l7-qubit-mzi.png

where the probability of measuring a single photon at the output is . Walking through this optical circuit, the states are found to be

such that

Repeating this times (so that we use the same average number of photons as in the coherent state case), we find that the standard deviation in is

Given this, the uncertainty in is

This is the same uncertainty as we obtained for the coherent state input, but the physical origin is different. Now, we see the noise as being due to statistical fluctuations of a Bernoulli point process, one event at a time. The noise thus comes from the amount of time the signal is integrated over (assuming a constant rate of photons). The noise is simply shot noise.